PRODUCT CERTIFICATIONS OVERVIEW All 475 Field Communicators come with the main unit label (see Figure B-1). Intrinsically Safe (KL option) 475 Field Communicators also have an additional label opposite the main unit label on the back of the Field Communicator. If the 475 Field Communicator does not contain this label (NA option), then it is considered non-IS approved. The Declaration of Conformity and other approval information are available on www.fieldcommunicator.com. The Federal Communications Commission (FCC), Industry Canada (IC), Telecommunications Regulatory Authority (TRA), and Radio and Telecommunications Terminal Equipment (R&TTE) approvals apply to only 475 Field Communicators licensed for Bluetooth. A labels appears on the back of the Field Communicator if it is licensed for Bluetooth. APPROVED MANUFACTURING LOCATIONS R. STAHL HMI Systems GmbH —Cologne, Germany FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the user’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any modifications made to this device that are not approved by Emerson Process Management may void the authority granted to the user by the FCC to operate this equipment. IC This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. 100 TELECOMMUNICATIONS REGULATORY AUTHORITY OMAN - TRA TRA/TA-R/0089/11 D080273 EUROPEAN DIRECTIVE INFORMATION - CE COMPLIANCE R&TTE (1999/5/EC) This equipment is in conformity with the Radio and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC, ETSI EN 300328:2006-10, and IEC 2209-2:2007 standards. Electro Magnetic Compatibility (2004/108/EC) Tested to the EN 61326-1:2006 and ETSI EN 301489-17:2002-08 specification. Low Voltage (2006/95/EC) Tested to the EN 61010-1:2001 specification. ATEX Directive (94/9/EC) (KL option only) See “European Certifications” for more information. HAZARDOUS LOCATIONS CERTIFICATIONS (KL OPTION ONLY) The Intrinsic Safety approvals listed in this section include compliance with the FISCO requirements. European Certifications ATEX Intrinsic Safety (KL option only) This equipment complies with the ATEX Directive (94/9/EC). Specific ATEX Directive Information is located within this section and in the 475 Field Communicator Getting Started Guide. Applicable standards EN 60079-0:2012, EN 60079-11:2012, and EN 60079-26:2007. Certification No.: BVS 09 ATEX E 022 II 2 G (1 GD) Ex ia [ia Ga] [ia Da IIIC] IIC T4 Gb (-10°C ≤ Ta ≤ +50°C) 0158 HART Intrinsically Safe Electrical Parameters Input Parameters Ui = 30 Volt DC Ii = 200 mA Pi = 1.0 Watt Li = 0 Ci = 0 101 FOUNDATION fieldbus The FISCO standard applies to the FM, CSA, IECEx, and ATEX certifications. Intrinsically Safe FISCO Intrinsically Safe Non-FISCO International Certification IECEx Certification No.: IECEx BVS 10.0094 Ex ia [ia Ga] [ia Da IIIC] IIC T4 Gb (-10°C ≤ Ta ≤ +50°C) HART Intrinsically Safe electrical parameters Input Parameters Output Parameters FOUNDATION fieldbus Intrinsically Safe FISCO Intrinsically Safe Non-FISCO North American Certifications Factory Mutual (FM) Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D and Class I, Zone 0, AEx ia IIC T4 (Ta = 50°C) hazardous locations when connected as indicated in the control drawing 00475-1130. See the control drawing for input and output parameters. Canadian Standards Association (CSA) Intrinsically Safe for use in Class I, Zone 0, Ex ia IIC T4 (Ta = 50°C) Output Parameters U0 = 1.9 Volt DC I0 = 32 μA UiIIC = 17.5 Volt DC IiIIC = 215 mA PiIIC = 1.9 Watt UiIIB = 17.5 Volt DC IiIIB = 380 mA PiIIB = 5.3 Watt U0 = 1.9 Volt DC I0 = 32 μA Ui = 30 Volt DC Ii = 380 mA Pi = 1.3 Watt U0 = 1.9 Volt DC I0 = 32 μA Li = 0 Ci = 0 Ui = 30 Volt DC Ii = 200 mA Pi = 1.0 Watt Li = 0 Ci = 0 U0 = 1.9 Volt DC I0 = 32 μA UiIIC = 17.5 Volt DC IiIIC = 215 mA PiIIC = 1.9 Watt UiIIB = 17.5 Volt DC IiIIB = 380 mA PiIIB = 5.3 Watt U0 = 1.9 Volt DC I0 = 32 μA Ui = 30 Volt DC Ii = 380 mA Pi = 1.3 Watt U0 = 1.9 Volt DC I0 = 32 μA 102 hazardous locations when connected as indicated in the control drawing 00475-1130. See the control drawing for input and output parameters. Please note the parameters in the control drawing are the same as the FM parameters. POWER SUPPLY/CHARGER CERTIFICATION Declaration of Conformity/Approvals The 475 Field Communicator power supply/charger complies to the requirements of the relevant EU directives. The conformity assessment process has been successfully completed as per the directives listed below. All approval information for this product can be accessed at www.fieldcommunicator.com. European Union Directives Low Voltage Directive 2006/95/EC EN 60950: 2001 + A11 EMC Directive 2004/108/EC The following harmonized standards were applied, immunity EN61204-3:2000 RoHS (2002/95/EC) directive WEEE (2002/96/EC) directive Japanese Directives DENAN/PSE LABEL DRAWINGS Figure B-1. All 475 Field Communicators have a similar label to the one below. 2009 08 50 1 Manufactured Exclusively for Fisher-Rosemount Systems, Inc. (an Emerson Process Management company) By R. STAHL HMI Systems GmbH D-50767 Cologne, Germany Use only with 475 Power Module 20nn Barcode 0158 475 Field Communicator Serial No. 1 2 3 4 5 6 7 8 44.0mm 33.0 mm Label 1-1 ZN:2009 08 50 1 R = 1.5 mm 103 Figure B-2. Approval Ex Label Example (Only on 475 Field Communicators with the KL