parts of timer


SUBMITTED BY: murshad

DATE: Jan. 15, 2016, 4:55 p.m.

FORMAT: Text only

SIZE: 2.4 kB

HITS: 546

  1. imers
  2. CT Range
  3. CT-D range CT-E range CT-S range
  4. Timing function multifunctional single-functional multifunctional single-functional multifunctional single-functional
  5. A ON-delay CT-MFD CT-ERD CT-MFE, CT-MKE CT-ERE, CT-EKE CT-MVS, CT-MFS,
  6. CT-MBS, CT-WBS
  7. CT-ERS
  8. B OFF-delay CT-MFD CT-AHD CT-MFE CT-AHE, CT-ARE,
  9. CT-AKE
  10. CT-MVS, CT-MFS,
  11. CT-MBS
  12. CT-APS, CT-AHS,
  13. CT-ARS, CT-VBS
  14. AB ON- and OFF-delay CT-MVS, CT-MXS,
  15. CT-MFS, CT-MBS
  16. CA Impulse-ON CT-MFD CT-VWD CT-MFE, CT-MKE CT-VWE CT-MVS, CT-MFS,
  17. CT-MBS, CT-WBS
  18. CB Impulse-OFF CT-MFD CT-AWE CT-MVS, CT-MFS,
  19. CT-MBS
  20. CE Impulse-ON and OFF CT-MXS
  21. DA Flasher
  22. starting with ON
  23. CT-MFD CT-EBD CT-MFE, CT-MKE CT-MFS, CT-MBS,
  24. CT-WBS
  25. DB Flasher
  26. staring with OFF
  27. CT-MFD CT-MFE, CT-MKE CT-EBE CT-MFS, CT-MBS,
  28. CT-WBS
  29. DE Flasher
  30. starting with ON or OFF
  31. CT-MVS
  32. ED Pulse generator starting
  33. with ON or OFF
  34. CT-TGD CT-MXS
  35. H Pulse former CT-MFD CT-MFE CT-MVS, CT-MFS,
  36. CT-MBS
  37. F Star-delta change-over CT-SDD, CT-SAD CT-SDS
  38. FC Star-delta change-over
  39. with impulse
  40. CT-SDE CT-MVS.2x,
  41. CT-MFS, CT-MBS
  42. FA Star-delta change-over
  43. twice ON-delayed
  44. CT-YDE
  45. A+ AC BC G
  46. further functions
  47. (depending on device)
  48. CT-MVS, CT-MXS,
  49. CT-MFS, CT-MBS,
  50. CT-WBS
  51. G Switching relay CT-IRE CT-IRS
  52. Technical data (extract)
  53. Time ranges 7 (0.05 s - 100 h)
  54. CT-SDD, CT-SAD: 4 (0.05 s - 10 min)
  55. Multifunction devices: 8 (0.05 s - 100 h)
  56. Single-function devices: 5 single ranges
  57. (0.05-1 s, 0.1-10 s, 0.3-30 s, 3-300 s,
  58. 0.3-300 min)
  59. 10 (0.05 s - 300 h)
  60. CT-ARS, CT-SDS: 7 (0.05 s- 10 min)
  61. Control supply voltage Wide and multi ranges Wide ranges Single and dual
  62. ranges
  63. Wide, multi and single ranges
  64. Type and number of contacts 1 or 2 c/o contacts
  65. CT-SDD, CT-SAD: 2 n/o contacts
  66. 1 c/ o contact
  67. CT-SDE: 1 n/o contact and 1 n/c contacts
  68. CT-MKE, CT-EKE, CT-AKE: 1 thyristor
  69. 1 or 2 c/o contacts
  70. CT-MVS.21, CT-MFS, CT-MBS: 2nd
  71. c/o contact selectable as inst. contact
  72. CT-SDS: 2 n/o contacts
  73. Control inputs voltage-related triggering, polarized, capable
  74. of switching a parallel load
  75. voltage-related triggering, polarized
  76. CT-MFE, CT-AHE, CT-AWE:
  77. with auxiliary voltage
  78. voltage-related triggering, non-polarized,
  79. capable of switching a parallel load
  80. CT-MFS, CT-MBS, CT-AHS:
  81. volt-free triggering
  82. General information
  83. Electronic timers
  84. Overview
  85. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com