  1. PRODUCT CERTIFICATIONS
  2. OVERVIEW All 475 Field Communicators come with the main unit label (see
  3. Figure B-1). Intrinsically Safe (KL option) 475 Field Communicators
  4. also have an additional label opposite the main unit label on the back
  5. of the Field Communicator. If the 475 Field Communicator does not
  6. contain this label (NA option), then it is considered non-IS approved.
  7. The Declaration of Conformity and other approval information are
  8. available on www.fieldcommunicator.com.
  9. The Federal Communications Commission (FCC), Industry Canada
  10. (IC), Telecommunications Regulatory Authority (TRA), and Radio and
  11. Telecommunications Terminal Equipment (R&TTE) approvals apply to
  12. only 475 Field Communicators licensed for Bluetooth. A labels appears
  13. on the back of the Field Communicator if it is licensed for Bluetooth.
  14. APPROVED
  15. MANUFACTURING
  16. LOCATIONS
  17. R. STAHL HMI Systems GmbH —Cologne, Germany
  18. FCC This equipment has been tested and found to comply with the limits for
  19. a Class A digital device, pursuant to part 15 of the FCC Rules. These
  20. limits are designed to provide reasonable protection against harmful
  21. interference when the equipment is operated in a commercial
  22. environment. This equipment generates, uses, and can radiate radio
  23. frequency energy and, if not installed and used in accordance with the
  24. user’s manual, may cause harmful interference to radio
  25. communications. Operation of this equipment in a residential area is
  26. likely to cause harmful interference in which case the user will be
  27. required to correct the interference at his own expense.
  28. This device complies with Part 15 of the FCC Rules. Operation is
  29. subject to the following two conditions: (1) this device may not cause
  30. harmful interference, and (2) this device must accept any interference
  31. received, including interference that may cause undesired operation.
  32. Any modifications made to this device that are not approved by
  33. Emerson Process Management may void the authority granted to the
  34. user by the FCC to operate this equipment.
  35. IC This Class A digital apparatus complies with Canadian ICES-003.
  36. Cet appareil numérique de la classe A est conforme à la norme
  37. NMB-003 du Canada.
  38. 100
  39. TELECOMMUNICATIONS
  40. REGULATORY
  41. AUTHORITY
  42. OMAN - TRA TRA/TA-R/0089/11 D080273
  43. EUROPEAN DIRECTIVE
  44. INFORMATION - CE
  45. COMPLIANCE
  46. R&TTE (1999/5/EC) This equipment is in conformity with the Radio and
  47. Telecommunications Terminal Equipment (R&TTE) Directive
  48. 1999/5/EC, ETSI EN 300328:2006-10, and IEC 2209-2:2007
  49. standards.
  50. Electro Magnetic
  51. Compatibility
  52. (2004/108/EC)
  53. Tested to the EN 61326-1:2006 and ETSI EN 301489-17:2002-08
  54. specification.
  55. Low Voltage (2006/95/EC) Tested to the EN 61010-1:2001 specification.
  56. ATEX Directive (94/9/EC)
  57. (KL option only)
  58. See “European Certifications” for more information.
  59. HAZARDOUS LOCATIONS
  60. CERTIFICATIONS (KL
  61. OPTION ONLY)
  62. The Intrinsic Safety approvals listed in this section include compliance
  63. with the FISCO requirements.
  64. European Certifications ATEX Intrinsic Safety (KL option only)
  65. This equipment complies with the ATEX Directive (94/9/EC).
  66. Specific ATEX Directive Information is located within this section and in
  67. the 475 Field Communicator Getting Started Guide.
  68. Applicable standards EN 60079-0:2012, EN 60079-11:2012, and EN
  69. 60079-26:2007.
  70. Certification No.: BVS 09 ATEX E 022
  71. II 2 G (1 GD) Ex ia [ia Ga] [ia Da IIIC] IIC T4 Gb (-10°C ≤ Ta ≤
  72. +50°C)
  73. 0158
  74. HART Intrinsically Safe Electrical Parameters
  75. Input Parameters
  76. Ui = 30 Volt DC
  77. Ii = 200 mA
  78. Pi = 1.0 Watt
  79. Li = 0
  80. Ci = 0
  81. 101
  82. FOUNDATION fieldbus
  83. The FISCO standard applies to the FM, CSA, IECEx, and ATEX
  84. certifications.
  85. Intrinsically Safe FISCO
  86. Intrinsically Safe Non-FISCO
  87. International Certification IECEx
  88. Certification No.: IECEx BVS 10.0094
  89. Ex ia [ia Ga] [ia Da IIIC] IIC T4 Gb (-10°C ≤ Ta ≤ +50°C)
  90. HART Intrinsically Safe electrical parameters
  91. Input Parameters
  92. Output Parameters
  93. FOUNDATION fieldbus
  94. Intrinsically Safe FISCO
  95. Intrinsically Safe Non-FISCO
  96. North American
  97. Certifications
  98. Factory Mutual (FM)
  99. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D and
  100. Class I, Zone 0, AEx ia IIC T4 (Ta = 50°C) hazardous locations when
  101. connected as indicated in the control drawing 00475-1130. See the
  102. control drawing for input and output parameters.
  103. Canadian Standards Association (CSA)
  104. Intrinsically Safe for use in Class I, Zone 0, Ex ia IIC T4 (Ta = 50°C)
  105. Output Parameters
  106. U0 = 1.9 Volt DC
  107. I0 = 32 μA
  108. UiIIC = 17.5 Volt DC IiIIC = 215 mA PiIIC = 1.9 Watt
  109. UiIIB = 17.5 Volt DC IiIIB = 380 mA PiIIB = 5.3 Watt
  110. U0 = 1.9 Volt DC I0 = 32 μA
  111. Ui = 30 Volt DC Ii = 380 mA Pi = 1.3 Watt
  112. U0 = 1.9 Volt DC I0 = 32 μA
  113. Li = 0 Ci = 0
  114. Ui = 30 Volt DC
  115. Ii = 200 mA
  116. Pi = 1.0 Watt
  117. Li = 0
  118. Ci = 0
  119. U0 = 1.9 Volt DC
  120. I0 = 32 μA
  121. UiIIC = 17.5 Volt DC IiIIC = 215 mA PiIIC = 1.9 Watt
  122. UiIIB = 17.5 Volt DC IiIIB = 380 mA PiIIB = 5.3 Watt
  123. U0 = 1.9 Volt DC I0 = 32 μA
  124. Ui = 30 Volt DC Ii = 380 mA Pi = 1.3 Watt
  125. U0 = 1.9 Volt DC I0 = 32 μA
  126. 102
  127. hazardous locations when connected as indicated in the control
  128. drawing 00475-1130. See the control drawing for input and output
  129. parameters. Please note the parameters in the control drawing are the
  130. same as the FM parameters.
  131. POWER
  132. SUPPLY/CHARGER
  133. CERTIFICATION
  134. Declaration of
  135. Conformity/Approvals
  136. The 475 Field Communicator power supply/charger complies to the
  137. requirements of the relevant EU directives. The conformity
  138. assessment process has been successfully completed as per the
  139. directives listed below. All approval information for this product can be
  140. accessed at www.fieldcommunicator.com.
  141. European Union Directives
  142. Low Voltage Directive 2006/95/EC
  143. EN 60950: 2001 + A11
  144. EMC Directive 2004/108/EC
  145. The following harmonized standards were applied, immunity
  146. EN61204-3:2000
  147. RoHS (2002/95/EC) directive
  148. WEEE (2002/96/EC) directive
  149. Japanese Directives
  150. DENAN/PSE
  151. LABEL DRAWINGS
  152. Figure B-1. All 475 Field Communicators have a similar label to the one below.
  153. 2009 08 50 1
  154. Manufactured Exclusively for
  155. Fisher-Rosemount Systems, Inc.
  156. (an Emerson Process Management company)
  157. By R. STAHL HMI Systems GmbH
  158. D-50767 Cologne, Germany
  159. Use only with 475 Power Module
  160. 20nn
  161. Barcode
  162. 0158
  163. 475 Field Communicator
  164. Serial No. 1 2 3 4 5 6 7 8
  165. 44.0mm
  166. 33.0 mm
  167. Label 1-1
  168. ZN:2009 08 50 1
  169. R = 1.5 mm
  170. 103
  171. Figure B-2. Approval Ex Label Example (Only on 475 Field Communicators with the KL

comments powered by Disqus